Fluke 5520A High Performance Multi-Product Calibrators

 Tip: click on the picture to zoom in
Technical Specifications
Voltage DC
Range:  0 to ±1020V
Best 1 Year Specification:  ±12 ppm of setting
Current DC
Range:  0 to ±20.5A
Best 1 Year Specification:  ±100 ppm of setting
Resistance
Range:  0 to 1100 MΩ
Best 1 Year Specification:  ±28 ppm of setting
Voltage AC
Range:  1 mV to 1020V
   10 Hz to 500 kHz, Sine
Best 1 Year Specification:  ±120 ppm of setting
Current AC
Range:  29 mA to 20.5A
   10 Hz to 30 kHz, Sine
Best 1 Year Specification:  ±0.06% of setting
Capacitance
Range:  0.19 nF to 110 mF
Best 1 Year Specification:  ±0.25% of setting
Thermocouple Source and Measure
Range:  -250°C to +2316°C (11 types)
Best 1 Year Specification:  ± 0.14°C of setting
RTD Source
Range:  -200°C to +630°C
   (8 types)
Best 1 Year Specification:  ±0.03°C of setting
DC Power
Range:  10.9 mW to 20.5 kW
Best 1 Year Specification:  ±0.023% of setting
AC Power
Range:  10.9 mW to 20.5 kW
   45-65 Hz, PF=1
Best 1 Year Specification:  ±0.08% of setting
Phase
Range:  0 to ± 179.99°
   10 Hz to 30 kHz
Best 1 Year Specification:  ±0.07° of setting
Frequency
Range:  0.01 Hz to 2.0 MHz
Best 1 Year Specification:  ±25 ppm of setting

 

General Specifications
Warm up Time
   Twice the time since last warmed up, to a maximum of 30 minutes
Settling Time
   Less than 5 seconds for all functions and ranges except as noted
Standard Interfaces
   IEEE-488 (GPIB), RS-232
Temperature Performance
Operating:  0°C to 50°C
Calibration (tcal):  15°C to 35°C
Storage:  -20°C to 70°C
Temperature Coefficient
   Temperature coefficient for temperatures outside tcal ± 5°C is 10% of the 90-day specification (or 1-year, as applicable) per °C
Relative Humidity
Operating:  <80% to 30°C, <70% to 40°C, <40% to 50°C
Storage:  <95%, non-condensing
Altitude
Operating:  3,050m (10,000 ft) maximum
Non-operating:  12,200m (40,000 ft) maximum
Safety
   12,200m (40,000 ft) maximum
Analog Low Isolation
   20V
EMC
   Designed to comply with IEC 61326-1/1997
Line Power
Line Voltage (selectable):  100V, 120V, 220V, 240V
Line Frequency:  47 to 63 Hz
Line Voltage Variation:  + 10% about line voltage setting
Power Consumption
   600 VA
Dimensions
Height:  17.8 cm (7 in), standard rack increment, plus 1.5 cm (0.6 in) for feet on bottom of unit
Width:  43.2 cm (17 in), standard rack width
Depth:  47.3 cm (18.6 in) overall
Weight (without options)
   22 kg (49 lbs.)
Absolute Uncertainty Definition
   5500A and 5520A uncertainty specifications include stability, temperature coefficient, linearity, line and load regulation, and the traceability of the external standards used for calibration. You do not need to add anything to determine the total uncertainty of your calibrator for the temperature range indicated.
Specification Confidence Interval
   > 99%